ELISA sphingotest® penKid®

€675,00

Enzyme-linked immunosorbent assay for the quantification of human Proenkephalin A 119-159 in plasma.


Intended Use


The ELISA sphingotest® penKid® is a non-automated one-step enzyme-linked immuno-sorbent assay (ELISA) for the quantitative measurement of human Proenkephalin A 119-159 in plasma. The product is for research use only. It is not intended for diagnostic or therapeutic purposes.

  • SPECIFICATIONS

    Assay type:  Enzyme-linked Immunosorbent Assay (ELISA)

    Assay format: One-step

    Plate type: 1 x 96 well plate

    Product status: RUO

    Sample type: EDTA plasma, heparin plasma

    Sample Volume: 50 µL

    Number of Calibrators: 1 vial (6 levels generated by the customer)

    Measuring Unit: pmol/L

    Measuring Range: 10 – 1,000 pmol/L

    Assay incubation time: 2.5 hours

    Lower Limit of Quantification (LoQ): 10.2 pmol/L (20% Total CV)

    Lower Limit of Detection (LoD): 8.9 pmol/L

    High Dose Hook: No high-dose hook effect up to 10.000 pmol/L

    Detection Method: Colorimetry (detection wavelength = 450 nm, reference wavelength = 570 nm)

    Storage Condition: 2-8°C

  • USAGE

  • DETAILS

    • CALIBRATOR: 1 vial, lyophilized for 0.5 mL, for generation of calibrator set (CAL1 to CAL5)
    • ZERO MATRIX: 1 bottle, 4 mL, liquid, for reconstitution of CALIBRATOR and its dilution, for use as zero calibrator (CAL0)
    • MICROPLATE: 1 pouched 96-well microplate, coated with anti-penKid monoclonal antibodies
    • TRACER: 1 bottle, lyophilized for 18 mL, contains HRP-labelled anti-penKid monoclonal antibody
    • BUFFER: 1 bottle, 18 mL, liquid, for reconstitution of TRACER
    • SUBSTRATE: 1 bottle, 11 mL, liquid, for HRP catalyzed TMB reaction
    • STOP SOLUTION: 1 bottle, 6 mL, liquid, for stop of substrate reaction
    • WASH CONCENTRATE: 1 bottle, 22 mL concentrate, liquid, for generation of 1.1 L wash solution
    • ADHESIVE FOIL: 2 black colored adhesive foils, for light protected incubations
    • PACKAGE INSERT: 1 Package Insert with instructions for use
    • QUALITY REPORT: 1 Quality report with lot numbers and calibration info


    Reagents and materials required but not provided


    • Microlitre pipettes covering a range of 50 – 500 µL with replace¬able plastic tip.
    • Multichannel pipette (150 µL) with replaceable plastic tip.
    • Polypropylene tubes (≥500 µL).
    • Vortex mixer.
    • Reagent reservoirs with capacity ≥18 mL (for pipetting tracer, substrate and stop solutions using a multichannel pipette).
    • Laboratory water grade 2 (acc. ISO 3696:1987).
    • Bottle with lid or screw cap (1,100 mL) to fit the ready-to-use wash solution
    • Automated microplate washing device (e.g. Wellwash, Thermo Scientific).
    • Microplate reader capable of reading absorbances at 450 nm and 570 nm (e.g. Spectra-Max ID5, Molecular Devices LLC).

BESTSELLERS

ALL PRODUCTS